Crossfire 8600/8605 Token-Ring Switches V. 1.2, P/N - Olicom CrossFire 8600 Manual To Operations

Token-ring switches
Table of Contents

Advertisement

- Network memory test 32-bits........Passed.
- Network memory test 16-bits........Passed.
- Network memory test 8-bits........Passed.
- Port register and memory test.....................Passed.
- Single port loopback test.....................Passed.
- All ports linked loopback test.....................Passed.
- Port MAC test.....Passed.
- Completed Power On Self Test Diagnostics.
System Software Version 03.05, Copyright 1994-1998.
System started on Tue. November 10, 1998 14:30:03
8 Megabytes System memory
2 Megabytes Network memory
- Initialization started
- File system initialized
- System temperature is within safe operating levels
- Checking file system integrity
- Warmboot initialization started
- LAN ports detected:
- RJ-45 Token Ring: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
- StkPort
- Initializing Ports: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
20 29
- Initializing system address table
- System entering stand-alone mode
- System initialization complete
Starting SNMP v1/v2c bilingual agent task
Total MIB objects: 1236
- Enabling port: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 29
Press RETURN key to activate console...
Depending upon which tests have run, verify that all diagnostics have passed and
that the ERR LED is off. If the ERR LED is on, read the screen to determine which
test failed. See also Chapter 10, "Troubleshooting" , to help find the cause.
At the end of the boot messages, you should be prompted to press
following greeting screen of the switch Console Manager should appear:

CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641

: 29
RETURN
Connecting a Network Management Console
73
. The

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crossfire 8605

Table of Contents