Serial Link Configuration Screen

Use the Serial Link Configuration screen to configure a switch when using a
modem to create a console session.
Hardware Flow Control
Enables or disables RTS/CTS handshaking.
Default: Disabled
Software Flow Control
Enables the XON and XOFF characters, which are 11 and 13 hexadecimal, respectively.
Default: Disabled
Autobaud Upon Break
Indicates whether the baud rate is reset when a Break key sequence (pressing
rapidly for five seconds) is sent or received. The default is Disabled . When
ENTER
set to enabled, a baud rate change can be accomplished by changing the baud rate
of the terminal emulator, disconnecting and reconnecting the TIA/EIA-232 cable,
and then pressing
until a screen appears.
ENTER
Console Baud Rate
The baud rate of the TIA/EIA-232 port. Acceptable baud rates for the console are
1200 , 2400 , 4800 , 9600 , 19200 , 38400 , 57600 , or Autobaud . The default value for
this parameter is 9600 . Make sure that your terminal emulator baud rate matches
the console baud rate you set.
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641