Reset Screen

The Reset screen is accessed from the main menu. The Reset screen, as shown
below, displays the reset options available with the switch.
Number of Resets Since Diagnostics
Number of times the switch has been reset since the switch was powered on or ran
power-on diagnostics. This is an informational heading; the data cannot be
changed.
This number is not reset to 0 when nonvolatile RAM is cleared.
The following four items within the Reset screen are command functions that you
can select and initiate by moving the highlight over the item and pressing
Reset Switch With Diagnostics
A reset function is initiated with this command. It resets the switch hardware; runs
diagnostic tests; clears all counters, including address tables; and restarts the
switch. When the switch reboots, administrative parameters from non-volatile
memory are used to initialize the operational parameters. This takes approximately
4 to 5 minutes.
Reset Switch Without Diagnostics
This command resets the switch hardware; clears all counters, including address
tables; and starts the switch. When the switch reboots, administrative parameters
from non-volatile memory are used to initialize the operational parameters. This
procedure takes approximately 40 seconds.
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
.