Settings in the Communications submenu define and control how single or multiple
projectors are can link with each other and with a controlling device.
Baud Rates
The baud rate setting determines the speed of communication to and from the
projector on the RS232 or RS422 links. The maximum rate for either standard is
115200. The default baud rate for use with the DHD Controller is 115200. If this is
changed, communication with the DHD Controller will be lost.
Projector
Enter a three-digit number (such as "001") to assign or change a number to the
projector currently in use. If the current projector already has a number assigned,
that number will appear here (for example, "004" in Figure 3.14, above). Numerical
identity for projectors enables you to communicate with a single projector within a
multiple-projector application. If you make a mistake in assigning or changing the
projector number, press Exit to cancel.
NOTE: This feature is not used when the projector is used with the DHD Controller.
Network Routing
NOTE: This feature is not applicable when the projector is used by itself, with the DHD
Controller or in a simple serial network with only one type of controller and linking.
SEPARATE: Select "Separate" (factory default) to keep RS232, RS422 and Ethernet
messages on their respective paths instead of being broadcast to the other types
of ports.