Problem
Problem cause
Pilot will not light
Gas valve may be
OFF
Tank fuel empty
Air in supply system
Loose connection
Pilot will not stay on Debris around pilot
Loose connection
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Burner will not light Pressure is low
Control valve not ON
Thermocouple bad
Pilot light assembly
bent or not in correct
location
Burner flame goes
Low gas pressure
off
immediately
after ignition
-

TROUBLESHOOTING

solution
Turn the gas valve ON
Refill LP gas tank
Purge air from lines
Check all fittings
Clean dirty area
Tighten connection
Replace thermocouple
Check connections
Fuel tank is near empty
Fuel tank is near empty
Turn valve to ON
Replace thermocouple
Place pilot in proper
Position and retry
Let the pilot flame stay lit
for 10 minutes before
setting variable knob to
"LO"