Troubleshooting - Fire Sense PH03-S Manual

Deluxe patio heater
Hide thumbs Also See for PH03-S:
Table of Contents

Advertisement

TROUblESHOOTING

PROblEM
POSSIblE CAUSE
Gas valve may be off
Fuel tank may be empty
Orifice blocked
Air in supply system
Loose connection
Main burner will
not light
Igniter fails
Gas pressure low with valve open full
New cylinder or 1st ignition
Cylinder valve on, no gas flow
AAA battery behind igniter button
is dead
Pressure is low
Tank is low on fuel
Low burner flame
Gas hose is kinked
Control Knob at max
Carbon on reflector & emitter screen
Burner unit
Thick black smoke
Contact us for assistance: (866) 985-7877 | www.wtliving.com
CORRECTIvE ACTION
Turn gas valve ON
Refill LPG tank
Clean or replace orifice
Purge air from lines. Open gas lines and depress Control
Knob for 2-3 mins.
Check all fittings
Use stick lighter to manually light
Replace cylinder or regulator
Purge air from lines
Replace hose/regulator assembly
Replace with a new AAA battery
Replace LPG tank
Fill LPG tank
Check & straighten or replace
Check for obstruction at passageways and orifices
Clean components as needed
Blockage in burner assembly—thoroughly clean burner
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph03-ss

Table of Contents