TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Gas valve may be off
Fuel tank may be empty
Air in supply system
Loose connection
Main burner will
Igniter fails
not light
Gas pressure low with valve open full
New cylinder or 1st ignition
Pressure is low
Tank is low on fuel
Gas hose is kinked
Burner unit
Thick black smoke
Questions, problems, missing parts?
Before returning to your retailer, our exceptional customer service is available.
Call us toll-free at (866) 985-7877
cservice@welltraveled.net, or go online and live chat at www.
Contact us for assistance: (866) 985-7877 | www.
CORRECTIVE ACTION
Turn gas valve ON
Purge air from lines pen gas lines and depress control knob
for 2-3 minutes.
Use stick lighter to manually light
Replace cylinder or regulator
Purge air from lines
Replace hose/regulator assembly
Replace LPG tank
Fill LPG tank
Check and straighten or replace
Clean components as needed
Blockage in burner assembly—thoroughly clean burner
email us at
.