ASSEMBLY

Check for Leak

Your patio heater has been checked at all factory connections for leaks,
but you should always check when you attach the LPG cylinder. To
check for leaks, follow these instructions:
--Assemble all gas connections;
--Connect regulator assembly to the propane tank;
--Make sure the heater valve is turned OFF.
1) Make soapy solution by mixing 1 part liquid dish soap and 3 parts
water.
2) Open the propane tank valve.
3) Spoon several drops (or use squirt bottle) of the soapy solution
onto the gas hose /regulator and regulator/cylinder connection.
4) Inspect the connections and look for bubbles.
5) If no bubbles appear the connection is safe.
6) If bubbles appear, there is leakage. Close the propane tank valve,
and loosen and re-tighten this connection.
7) Check for leakage again.
8) If bubbles still appear and the leak is with the regulator or hose,
close the propane tank valve and contact customer support. If a leak
is detected, DO NOT attempt to use the heater.
MAKE SURE to check all THREE connections between the cylinder and gas
line.
-