SB Error

Message: "Critical Interrupt Sensor, Correctable, MCU Parity Error"
Table 1-6. SB Error
Byte
Field
1
NetFunLun
2
Platform Event Command
3
Generator ID
4
Event Message Format
Version
5
Sensor Type
6
Sensor Number
7
Event Direction Event Type
8
Event Data1
9
Event Data2
10
Event Data3
Value
Description
10h
02h
01h
Generated by BIOS
04h
Event Message Format Revision.
04h for this specification
13h
Critical Interrupt
77h
SB Sensor ID (depend on
platform)
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
AXh
07h: Correctable
08h: Uncorrectable
XXh
Bit 7:5Reserved Local error bit
number (4 ~ 0)
00000b: HT Periodic CRC Error
00001b: HT Protocol Error
00010b: HT Flow-Control Buffer
Overflow
00011b: HT Response Error
00100b: HT Per-Packet CRC Error
00101b: HT Retry Counter Error
00111b: MCU Parity Error
FFh
FFh: Not Present