Sb Error - Dell PowerEdge C6220 II Hardware Owner's Manual

Servers
Hide thumbs Also See for PowerEdge C6220 II:
Table of Contents

Advertisement

SB Error

Message: "Critical Interrupt Sensor, Correctable, MCU Parity Error"
Byte
Field
1
NetFunLun
2
Platform Event Command
3
Generator ID
4
Event Message
Format Version
5
Sensor Type
6
Sensor Number
7
Event Direction
Event Type
8
Event Data1
9
Event Data2
10
Event Data3
42
|
About Your System
Value
Description
10h
02h
01h
Generated by BIOS
04h
Event Message Format
Revision. 04h for this
specification.
13h
Critical Interrupt
77h
SB Sensor ID (depend on
platform)
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
AXh
07h: Correctable
08h: Uncorrectable
XXh
Bit 7:5Reserved
Local error bit number (4 ~ 0)
00000b: HT Periodic CRC
Error
00001b: HT Protocol Error
00010b: HT Flow-Control
Buffer Overflow
00011b: HT Response Error
00100b: HT Per-Packet CRC
Error
00101b: HT Retry Counter
Error
00111b: MCU Parity Error
FFh
FFh: Not Present

Advertisement

Table of Contents
loading

Table of Contents