3.
Pull the DIMM baffle straight up and out.
To replace the component, reverse the removal procedure.

DIMMs

The memory subsystem supports only DDR3 SDRAM technology using industry-standard 1.2" high
DIMMs.
Single DIMM
sizes
2 GB
4 GB
8 GB
16 GB
CAUTION:
DIMM, or the DIMM load order must be adjusted.
1.
Power off the server blade and remove it from the server blade enclosure
server blade for
2.
Remove the access panel
3.
Locate the DIMM slots on the server blade system board
4.
Remove the DIMM baffle
5.
Open the DIMM slot latches.
1 16
Removing and replacing components
BL860c i2 Min / Max
BL870c i2 Min / Max
Memory size
Memory size
8 GB / 48 GB
Not supported
8 GB / 96 GB
16 GB / 192 GB
16 GB / 192 GB
32 GB / 384 GB
32 GB / 384 GB
64 GB / 768 GB
When a single DIMM is removed it must either be replaced with a new matching