Processor Fan Bracket

To remove the processor fan bracket:
1. Prepare the server for a non-hot-plug procedure. Refer to "Preparing the Server for
Non-Hot-Plug Procedures" in this chapter.
2. Remove the front bezel door (tower model only), and lay the server on its side with the
access panel facing upward. Refer to "Removing the Front Bezel Door (Tower Model
Only)" in this chapter.
3. Remove the access panel. Refer to "Removing the Access Panel" in this chapter.
4. Remove the hot-plug fans. Refer to "Hot-Plug Fans (Processor and I/O)" in this chapter.
5. Remove the fan basket. Refer to "Fan Basket" in this chapter.
6. Open the system tray. Refer to "Opening the System Tray" in this chapter.
7. Disconnect the processor fan bracket power cable from the system board.
8. Remove the four Torx T-15 screws securing the processor fan bracket to the chassis (1).
9. Slide the bracket toward the center of the chassis and lift the bracket out of the
chassis (2).
Figure 2-46: Removing the processor fan bracket
Reverse steps 1 through 9 to replace the processor fan bracket.
HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide
Removal and Replacement Procedures
2-55