Re-Entering The Server Serial Number - HP ProLiant ML570 Generation 2 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML570 Generation 2:
Table of Contents

Advertisement

Removal and Replacement Procedures

Re-entering the Server Serial Number

After replacing the system tray or clearing the NVRAM, the server serial number must be re-
entered. To re-enter the serial number:
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the System Options menu.
3. Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press the Escape key to exit RBSU.
7. Press the F10 key to confirm exiting RBSU. The server will automatically reboot.