Table 4.30 Mode Select Parameters: Informational Exception Control Page - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

Command Specifications
c.
Standby (unsupported)
Specifies whether to permit the IDD to enter the Standby condition if the IDD
does not receive a command within the time specified in the "Standby
Condition Timer" field.
If "1" is specified, the IDD is permitted to enter the Standby condition after
the elapse of the time specified in the "Standby Condition Timer" field.
If "0" is specified, the IDD is prohibited from entering the Standby condition.
d.
Standby Condition Timer (unsupported)
Specifies the time before the IDD enters the Standby condition. When the
Standby bit is "1," the IDD enters the Standby condition after the elapse of
the time calculated by multiplying the value specified in this field by 100 ms.
(11) Informational exceptions control page (page code = 1C)

Table 4.30 MODE SELECT parameters: informational exception control page

Bit
Byte
0
1
2
Default
Variable
3
Default
Variable
4-7
Default
Variable
8-11
Default
Variable
This page specifies whether the drive failure prediction function is enabled or
disabled and the reporting method when a drive failure is predicted.
a.
LogErr (log error)
This bit (LogErr) of zero indicates that the logging of informational exception
conditions within a target is vendor specific. A LogErr bit of one indicates
the target logs informational exception conditions.
4-64
7
6
5
0
0
0
Page length (X'0A')
Perf
0
EBF
EWASC DExcpt
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
Test
0
1
0
1
1
1
0
MRIE
0
0
0
0
0
1
Interval Timer
X'00000000'
X'FFFFFFFF'
Report Count
X'00000001'
X'FFFFFFFF'
1
0
0
0
0
LogErr
0
0
0
1
0
0
1
1