Mode Select (15); Table 4.12 Read Capacity Data - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

Bit
7
Byte
0
1
2
3
4
5
6
7

4.1.4 MODE SELECT (15)

Bit
7
Byte
0
1
0
2
0
3
0
4
5
0
This command performs setting and changing of each type of parameter related to
disk drive physical attributes, data format, timing of FC interface transferring
processing and error recovery procedures, etc. The INIT can know the types of
parameters, the current settings of each parameter and the types of parameters
which can be changed, and the ranges for such changes, etc. by using the MODE
SENSE or MODE SENSE EXTENDED command.
The data (MODE SELECT parameters) transferred from the INIT to the IDD by
this command, are configured from a "Header," "Block Descriptor" and one or
more "Page Descriptors" which describe each parameter, each of which will be
explained later.
C141-C009

Table 4.12 READ CAPACITY data

6
5
4
Logical Block Address (MSB)
Logical Block Address
Logical Block Address
Logical Block Address (LSB)
Block Length (MSB)
Block Length
Block Length
Block Length (LSB)
6
5
4
X'15'
0
0
PF
0
0
0
0
0
0
Parameter List Length
0
0
0
4.1 Control/Sense Commands
3
2
1
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SP
0
0
0
4-17