Table 4.71 Start-Stop Cycle Counter Page (X'0E'); Table 4.72 Date Of Manufacture (Page 0E, Code 0001) - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

Command Specifications
(8) Start-stop cycle counter page (X'0E')

Table 4.71 Start-stop cycle counter page (X'0E')

Bit
Byte
0
1
2
3
All of the following parameters have this header.
Page Length will be defined based on the value of Parameter Pointer. (CDB 5-6)
Date of manufacture (page 0E, code 0001)

Table 4.72 Date of manufacture (page 0E, code 0001)

Bit
Byte
4
5
6
7
8
9
10
11
12
13
The year and week in the year that the device was manufactured shall be set in the
parameter field defined by parameter code 0001h. The date of manufacture shall
not be savable by the INIT using the LOG SELECT command. The date is
expressed in numeric ASCII characters (30h-39h) in the form YYYYWW, as
shown above.
4-108
7
6
5
0
0
0
Page Length (MSB)
Page Length (LSB)
7
6
5
(MSB)
X'0001' (Parameter code)
(Date of Manufacture)
DU
DS
TSD
0
1
0
X'06' (Parameter Length)
(MSB)
Year of manufacture (4 ASCII characters)
(MSB)
Week of manufacture (2 ASCII characters)
4
3
2
0
1
1
X'00' (Reserved)
4
3
2
ETC
TMC
0
0
0
1
0
1
0
1
0
(LSB)
LBIN
LP
0
1
(LSB)
(LSB)
C141-C009

Advertisement

Table of Contents
loading

Table of Contents