Write Extended (2A) - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

Command Specifications

4.2.4 WRITE EXTENDED (2A)

Bit
Byte
0
1
2
3
4
5
6
7
8
9
This command transfers the number of blocks of data specified in the "Transfer
block count" field from the INIT and writes them in continuous logical data
blocks with the logical data block on the disk media specified in the "Logical
block address" field in the CDB as the top.
The functions of this command are the same as those of the Group 0 WRITE
command (Section 4.2.3) with the exception that it is possible to specify 4-byte
logical block addresses and 2-byte transfer block counts. However, when zero is
specified for the "Transfer block count," the command is terminated normally
without pre-fetch being performed.
In this device, specifications to the "FUA" bit in CDB byte 1 are invalid and
operation is as if zero is specified.
The specification of bit 4 of CDB byte 1 is invalid and the specified value is
disregarded.
4-140
7
6
5
0
0
0
Logical Block Address (MSB)
Logical Block Address
Logical Block Address
Logical Block Address (LSB)
0
0
0
Transfer Block Count (MSB)
Transfer Block Count (LSB)
0
0
0
4
3
2
X'2A'
×
FUA
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
C141-C009