Table 4.43 "Page Code" Assignment For The Log Pages - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

Command Specifications
The "PC" bits are ignored by the drive. The drive assumes that current cumulative
parameters are selected.
The "Page Code" field identifies which page of data is being requested. If the
page code is reserved or not implemented, the device server terminates the
command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid
field in CDB [=24-00]).
The "Page Code" assignments for the log pages are listed in Table 4.43.

Table 4.43 "Page Code" assignment for the log pages

Page Code
00
01
02
03
05
06
0D
0E
0F
10
18
2F
38
The "Parameter Pointer" field allows the application client to request parameter
data beginning from s specific parameter code to the maximum allocation length
or the maximum parameter code supported by the target, whichever is less. If the
value of the "Parameter Pointer" field is larger than the largest available
parameter code known to the device server for the specified page, the IDD
terminates the command with CHECK CONDITION status (ILLEGAL
REQUEST [=5] / Invalid field in CDB [=24-00]).
The "Parameter List Length" field in the CDB specifies the total number of bytes of
log parameter which can be transferred to the INIT by this command. The IDD
transfers the number of bytes of all log parameters specified in the "Page Code"
field or the portion of log parameters with the length specified in the "Parameter
List Length" field, whichever is smaller. When zero is specified in the "Parameter
List Length" field, this command is terminated without anything being transferred.
4-92
Description
Supported Log Pages
Buffer Overrun / Underrun Page
Write Error Counter Page
Read Error Counter Page
Verify Error Counter Page
Non-medium Error Page
Temperature Page
Start-stop Cycle Counter Page
Application Client Log Page
Self-Test Result Log Page
SAS Protocol Log Page
SMART Status Page
SMART Data Page
Parameter Pointer
Ignored
Supported
Supported
Supported
Supported
Should be zero
Supported
Supported
Supported
Supported
Ignored
Ignored
Ignored
C141-C009

Advertisement

Table of Contents
loading

Table of Contents