7) LP (List Parameter)
"1": The parameter is a data counter.
"0": The parameter is a list parameter.
If these bits are specified by LOG SELECT command, the IDD terminates
normally.
But the IDD's action is not changed.
For LOG SENSE command, these bits always report value defined in each
log page (see 4.2).

4.1.16 LOG SENSE (4D)

Bit
7
Byte
0
0
1
2
PC
0
3
0
4
5
6
7
8
9
0
This command provides a means for the application client to retrieve statistical or
other operational information maintained by the device about the device or its
logical units.
It is a complementary command to the LOG SELECT command.
The "Parameter Pointer Control (PPC)" bit is not supported. It should be zero.
An "Save Parameters (SP)" bit of zero indicates the device server performs the
specified this command and does not save any log parameters. If saving log
parameters is implemented, an "SP" bit of one indicates that the device server
performs the specified this command and saves all log parameters identified as
savable by the "DS" bit to the disc medium.
The "Page Control (PC)" field defined the type of parameter values to be selected
(see 4.1.15 for the definition of the page control field).
C141-C009
6
5
4
0
0
0
0
0
0
0
0
0
Parameter Pointer (MSB)
Parameter Pointer (LSB)
Parameter List Length (MSB)
Parameter List Length (LSB)
0
0
0
4.1 Control/Sense Commands
3
2
X'4D'
0
0
Page Code
0
0
0
0
0
0
1
0
PPC
SP
0
0
0
0
0
0
4-91