Table 6.5 Sense data error classification (3/3)
K*
C*
Q*
6
29
xx
Power on, reset, or HARD RESET occurred
The HDD was initialized by a Power on or HARD RESET
sequence.
6
2A
01
Mode parameters changed
The MODE SELECT parameters were changed by
another INIT.
6
2F
00
Commands cleared by another INIT
Commands were cleared by another INIT.
6
3F
01
Microcode has been changed
02
Changed operation definition
7
27
00
Write protected
Access to a read protected or write protected.
B
03
xx
Peripheral device write fault
11
xx
Unrecovered read error
13
xx
Sync byte not found for data field
14
xx
Record not found
15
xx
Mechanical positioning error
B
0E
01
Information Unit Too Short
02
Information Unit Too Long
47
01
Information Unit iuCRC Error Detected
4B
01
Invalid Target Port Transfer Tag Received
4B
02
Too Much Write Data
4B
03
ACK/NAK Time Out
4B
04
NAK Received
4B
05
Data Offset Error
4B
06
Initiator Response Timeout
An unrecoverable SAS related error occurred in the
command execution sequence.
B
4E
00
Overlapped commands attempted
Before execution of a command was completed, a new
command was issued by the same INIT.
E
1D
00
Miscompare during verify operation
Data failed to match in the Byte check mode of the
Verify command.
*
K: Sense Key
Q: Additional Sense Code Qualifier
C141-C013
6.2 INIT Error Recovery Methods (Recommended)
Outline of Error
C: Additional Sense Code
L: Logging Necessary? (shown in Section 6.2.3)
Recovery Method
L*
(See Table 6.6.)
None
14
None
21
None
25
None
27
None
15
Need
12
Need
6
None
2
None
24
377