Table 6.4 Additional Sense Code and Additional Sense Code Qualifier (3/6)
C*
Q*
Name
1C
01
Primary defect list not found
02
Grown defect list not found
80
SA information list not found The SA information (MODE SELECT parameter) header is
1D
00
Miscompare during verify
operation
80
Miscompare during self-
configuration
1F
00
Partial Defect List Transfer
20
00
Invalid command operation
code
21
00
Logical block address out of
range
24
00
Invalid field in CDB
25
00
Logical unit not supported
26
00
Invalid field in parameter list There is an error in the parameter list specifications transferred
27
00
Write protected
29
01
Power on occurred
02
SCSI Bus Reset Occurred
03
TARGET RESET function
occurred
04
Firmware Internal Reboot
07
I_T Nexus Loss occurred
2A
01
Mode parameter changed
03
Reservations preempted
04
Reservations released
05
Registrations preempted
2F
00
Command cleared by another
INIT
* C: Additional Sense Code, Q: Additional Sense Code Qualifier
C141-C013
Explanation
The defect list (P List) header is incorrect.
The defect list (G List) header is incorrect.
incorrect.
Comparison of data transferred from the INIT by a VERIFY
command (when the Byte Check mode was specified) with data
read from the disk media was terminated unsuccessfully.
There is an unmatch to compare read data with write data during
self-configuration.
Read Defect Data command (37h) cannot transfer all the Defect
data in the target because the numbers of defect exceeded the
maximum.
CDB byte 0 (operation code) is illegal.
A logical block address which exceeds the drive's maximum
value was specified.
There is an error in a specification in the CDB.
An illegal LUN was specified.
from the INIT during command execution.
A write operation was attempted in a write protected area. Or a
write operation is prohibited at the external operation panel.
Microcode was downloaded immediately after power on.
A HARD_RESET primitive was received.
A Logical Unit RESET was received.
Reboot occurred in the firmware
I_T Nexus Loss Time (Mode Page 19) was expired.
The MODE SELECT parameter values were changed by another INIT.
A persistent reserve state was cleared by another INIT.
A persistent reserve state was released
A persistent reserve state was preempted by another INIT.
A command was forcibly terminated by another INIT during
execution or queuing.
By a CLEAR TASK SET
The sense hold state was entered when the QErr bit was set on
"1."
6.1 Sense Data
Sense
key
3
3
3
E
E
1
5
5
5
5
5
7
6
6
6
6
6
6
6
6
6
6
367