Accounting date (page 0E, code 0002)

Table 5.51 Accounting date (page 0E, code 0002)

Bit
Byte
4
5
6
7
8
9
10
11
12
13
The Accounting date specified by parameter code 0002h is a parameter that may
be savable using a LOG SELECT command to indicate when the device was
placed in service. If the parameter is not yet set or is not settable, the default value
placed in the parameter field shall be 6 ASCII blank characters (20h). The field
shall not be checked for validity by the device server.
Specified cycle count over device lifetime (page 0E, code 0003)

Table 5.52 Specified cycle count over device lifetime (page 0E, code 0003)

Bit
Byte
4
5
6
7
8
9
10
11
C141-C013
7
6
5
(MSB)
X'0002' (Parameter code)
(Accounting Date)
DU
DS
TSD
0
0
0
X'06' (Parameter Length)
(MSB)
Accounting date Year (4 ASCII characters)
(MSB)
Accounting date week (2 ASCII characters)
7
6
5
(MSB)
X'0003' (Parameter code)
(Specified Cycle Count Over Device Lifetime)
DU
DS
TSD
0
1
0
X'04' (Parameter Length)
(MSB)
Specified Cycle Count Over Device Lifetime
(4-byte binary number)
4
3
2
ETC
TMC
0
0
0
4
3
2
ETC
TMC
0
0
0
5.2 Log Parameters
1
0
(LSB)
LBIN
LP
0
1
(LSB)
(LSB)
1
0
(LSB)
LBIN
LP
1
1
(LSB)
345