Table 5.35 Total Recoverable Read Errors Posted To Init (Page 03, Code 0003); Table 5.36 Total Read Bytes Processed (Page 03, Code 0005) - Fujitsu MBA3073RC SERIES Technical Manual

Disk drives serial attached scsi interface specifications
Hide thumbs Also See for MBA3073RC SERIES:
Table of Contents

Advertisement

Total recoverable read errors posted to INIT (page 03, code 0003)

Table 5.35 Total recoverable read errors posted to INIT (page 03, code 0003)

Bit
Byte
4
5
6
7
8
9
10
11
The Counter Value indicates the count of all posted recovered (01/xx/xx) errors to
the interface during read operations. The value includes the count of all posted
recovered verify errors (page X'05', Parameter code X'0003').
Total read bytes processed (page 03, code 0005)

Table 5.36 Total read bytes processed (page 03, code 0005)

Bit
Byte
4
5
6
7
8
9
~
~
16
17
The Total Read Bytes Processed indicates the total processed bytes during read
operation.
The bytes includes the total processed bytes during verify operation. (page X'05',
Parameter code X'0005')
C141-C013
7
6
5
(MSB)
X'0003 (Parameter code)
(Total Posted Recoverable Errors)
DU
DS
TSD
0
0
0
X'04' (Parameter Length)
(MSB)
7
6
5
(MSB)
X'0005' (Parameter code)
(Total Bytes Processed)
DU
DS
TSD
0
0
0
X'0A' (Parameter Length)
(MSB)
~
Total Write Bytes Processed (10 bytes)
~
4
3
2
ETC
TMC
0
0
0
Counter Value
4
3
2
ETC
TMC
0
0
0
5.2 Log Parameters
1
0
(LSB)
LBIN
LP
0
0
(LSB)
1
0
(LSB)
LBIN
LP
0
0
~
~
(LSB)