Table 6.3 Sense Key - Fujitsu MBA3073RC SERIES Technical Manual

Disk drives serial attached scsi interface specifications
Hide thumbs Also See for MBA3073RC SERIES:
Table of Contents

Advertisement

Sense Data and Error Recovery Methods
Sense
Name
Key
0
NO SENSE
1
RECOVERED ERROR 1) Indicates that the command which was executed last was terminated normally
2
NOT READY
3
MEDIUM
ERROR
4
HARDWARE ERROR
5
ILLEGAL REQUEST
6
UNIT
ATTENTION
7
DATA
PROTECT
8
BLANK CHECK
9
(Reserved)
A
COPY ABORTED
B
ABORTED
COMMAND
C
EQUAL
D
VOLUME
OVERFLOW
E
MISCOMPARE
F
(Reserved)
364

Table 6.3 Sense key

The specific sense key does not exist.
with a recovery operation by the HDD. If multiple errors which were
successfully recovered from during processing of a single command occurred,
the last error to have occurred is reported.
2) Rounding processing of the MODE SELECT parameter was performed.
The disk drive is not in a state where it can be accessed.
An irrecoverable error was detected due to a defect in the disk media or an error in
the recorded data.
The HDD detected an error in the hardware for which recovery processing is impossible
during command execution or self-diagnosis.
An illegal value was detected in the parameter transferred in the CDB or the
specification in the command. Also, an error in the LUN specification. If the
HDD detects an illegal parameter in the CDB, it terminates the command without
changing the contents of the disk media. If an illegal parameter is detected in the
parameters transferred from the INIT, the contents of the disk media may be
changed by that command.
A UNIT ATTENTION condition occurred.
1) An illegal operation was attempted in an area where a read or write operation is
prohibited. In this case, that command is not executed.
2) A SET LIMITS command was issued 2 times in a group of commands linked
in a series.
Not Used
Not Used
Not Used
The HDD terminated a command abnormally during execution. Normally, the INIT can
attempt to recover by reissuing that command.
Not Used
Not Used
During execution of a Byte Check with the VERIFY command, the data
transferred from the INIT were compared to the data read from the disk drive, but
they did not match.
Not Used
Explanation
C141-C013

Advertisement

Table of Contents
loading