5.2.13 SMART Status Page (X'2F')

Bit
Byte
0
1
2
3
4
~
~
n
This page contains parameters which allow the application client to check the
predictive drive failure condition of the HDD. The application client can check
whether the HDD has predicted a drive failure by periodically reading out this page.
The "Page Length" field indicates the length (byte length) after byte 4.
The "SMART Status Parameter" field is Fujitsu unique parameters. The details of
this field are outside the scope of this manual.

5.2.14 SMART Data Page (X'38')

Bit
Byte
0
1
2
3
4
~
~
n
This page reports data which the HDD collects for predicting drive failures.
The "Page Length" field indicates the length (byte length) after byte 4.
The "Log Parameters" field is Fujitsu unique parameters. The details of this field
are outside the scope of this manual.
C141-C013

Table 5.66 SMART status page (X'2F')

7
6
5
0
0
1
~
SMART Status Parameter
~

Table 5.67 SMART data page (X'38')

7
6
5
0
0
1
~
~
[Fujitsu unique page]
4
3
2
0
1
1
X'00' (Reserved)
Page Length (MSB)
Page Length (LSB)
[Fujitsu unique page]
4
3
2
1
1
0
X'00' (Reserved)
Page Length (MSB)
Page Length (LSB)
Log Parameters
5.2 Log Parameters
1
0
1
1
~
~
1
0
0
0
~
~
357