Electrical system

Microswitch cutting unit

Rider 15V2 and Pro 15
1. Loosen the right-hand wing cover.
2. Remove the inner protecting plate on the gear
lever carrier.
3. Disconnect the connector from the microswitch.
4. Remove the microswitch.
Assembling is done in the reverse order without
setting.
Rider Pro 18
The microswitch is placed in the frame tunnel.
When replacing the microswitch, a new setting is
required:
Check that the dome nut for the chain segment is in
position for maximum effect of the microswitch.
Adjust the microswitch so that it is definitely
activated by the dome nut, but allows extra motion
(must not bottom out).
68
– English
www.mymowerparts.com

Microswitch: Neutral Position

1. Remove the transmission cover.
2. Check the hydrostatic cable adjustment.
3. Adjust the microswitch so that it is activated by
the highest point in the hydrostatic arm's path
when no driving pedal is pressed.
4. Adjust the microswitch so that it is definitely
activated by the hydrostatic arm, but allows
extra motion (it must not bottom out). Tip: Hold
a feeler gauge between the switch and the arm
when making the adjustment.
5. Replace the transmission cover.

Microswitch seat

In certain cases it may be necessary to remove the
seat from the chassis.
The microswitch is located on the underside of the
seat and can be replaced together with the holder
without adjustment. The switch inside the holder
cannot be replaced alone as it is glued into place.