2-19. IGNITOR ASSEMBLY

Replacement
2-19
The 390 has electronic spark ignition, that lights a standing pilot.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING GAS CONTROL
VALVE DO THE FOLLOWING:
• MOVE THE POWER SWITCH TO THE
OFF POSITION.
• DISCONNECT THE MAIN CIRCUIT BREAKER AT
THE WALL, OR UNPLUG THE POWER CORD.
• TURN OFF THE MAIN GAS SUPPLY TO THE
FRYER AND DISCONNECT AND CAP THE SUPPLY
LINE TO FRYER, OR POSSIBLE.
2. Remove the control panel as discussed in Complete Control
Panel Section.
3. Disconnect the 1/4" gas line fitting from the pilot assembly.
4. Follow the wire from the spark ignitor to the module, and remove
the wire from the module.
5. Remove the left, or right side panel, depending upon which
ignitor assembly to be removed.
6. Disconnect gas line (for the left ignitor assembly).
7. Remove the 4 screws securing the burner assembly, and pull the
assembly from the unit.
8. Using a Phillips head screwdriver, remove the screw securing
the ignitor assembly to the burner assembly, and pull the ignitor
assembly from the unit.
9. Secure the new assembly with the screw previously removed,
making sure the assembly is turned to provide a 1/8" gap be-
tween the spark ignitor and the hood of the pilot assembly.
Model OFG- 390