Drain Valve And Extension - Henny Penny OFG-392 Technical Manual

Open fryer
Table of Contents

Advertisement

2-14. DRAIN VALVE
AND EXTENSION
Replacement
2-15
The drain valve opens when the drain valve handle is pulled out
and drains the shortening out of the pot.
1. Using a 3/8" socket, remove the nuts securing the drain switch
bracket, and pull the bracket from the studs.
2. Remove the nut securing the drain handle and pull the handle
from the drain valve.
3. Using a large adjustable wrench, unscrew the drain valve and
extension from the unit.
4. Replace the drain valve and extension.
5. Replace the drain switch bracket.
6. Adjust the microswitch to be no more than 1/8" (3 mm) from
the shaft of the drain valve.
NOTE: Listen for click of switch while pulling drain
valve handle.
Model OFG- 390
1003