Problem
Product color not
correct:
A. Too dark
B. Too light
C. Product
greasy
1003
Cause
COOKING SECTION
Temperature too high
Faulty temperature probe
Shortening too old
Shortening too dark
Breading product too far
in advance
Temperature too low
Fryer incorrect preheat
Slow fryer heat-up/recovery
Wrong cook button
pushed
Shortening old
Temperature too low
Faulty temperature probe
Frypot overloaded
Product not removed from
frypot immediately after
end of cycle
Model OFG- 390
Correction
Check temperature setting
in the program mode; see
section on programming
Remove and replace
temperature probe
Change shortening
Filter shortening
Change shortening
Bread product closer to
actual frying period
Check temperature setting
Remove and replace probe
Allow proper preheat time
Check gas pressure and blower
airflow
Be sure to select the
correct product to be cooked
Replace shortening
Check temperature setting
Temperature not recovered
when product was dropped
in frypot
Remove and replace defective
temperature probe
Reduce cooking load
Remove product from
frypot immediately after
end of cycle