2-15. AIR VALVE

1003
The air valve allows circulation of the shortening in the frypot to
keep the shortening at a uniform temperature.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the left side panel.
3. Remove the wires from the wire nuts.
4. Disconnect union at the valve.
5. Loosen the nut on the conduit connector and pull coil from
conduit.
6. Remove close nipple and female part of union from valve body.
7. Replace with new valve in reverse order.