2-4. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
2-5. POWER SWITCH
Checkout
1003
11. Pull excess capillary line from pot and tighten nut into frypot wall.
Be sure capillary bulb of high limit is positioned so it doesn't
interfere with the carrier or get damaged when cleaning the
frypot.
12. With excess capillary line pulled out, tighten smaller nut.
13. Replace front panel.
14. Refill with shortening.
The POWER switch is a three way rocker switch with a center
OFF position. With the switch in the ON position the fryer
operates. With the switch in the PUMP position the filter pump
operates, but the unit will not heat.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove control panel.
2. Label and remove wires from the switch.
3. OFF position-should be open circuit anywhere on the switch.
4. ON position. Check from: #5 to #6 closed circuit
5. Pump position. Check from: #4 to #5 closed circuit
Check across the jumpers on the wires of the POWER
switch. These jumpers have resistors and capacitors which may
be faulty.
Model OFG- 390
#l to #2 closed circuit
#3 to #2 closed circuit
2-4