Problem
Foaming or boiling
over of shortening
Shortening will
not drain from
frypot
Shortening leaking
1003
Cause
SHORTENING FOAMING/DRAINING SECTION
Water in shortening
Improper or bad
shortening
Improper filtering
Cold zone full of cracklings
Improper rinsing after
cleaning the fryer
Drain valve clogged with
crumbs
Drain valve will not open by
pulling the handle
Obstruction in drain
Faulty drain valve
Model OFG- 390
Correction
At end of Cook Cycle,
drain shortening and clean
frypot; add fresh shortening
Use recommended
shortening
Refer to the procedure
covering filtering the
shortening
Filter shortening
Clean and neutralize the
frypot; rinse with vinegar
to remove the alkaline, then
rinse with hot water and
dry frypot
Open valve - push cleaning
rod through drain opening
from inside of frypot
Replace cotter pins in valve
coupling
Remove obstruction
through drain
valve
Replace drain valve
1-9