7.4.3

TIMEOUT CONFIGURATION

The AMR timeout in the Module setup page of the SCA is a way to ensure that a connected
electricity meter communicates in only one way at any given time: UDP, TCP or via the web server.
The timeout is locked to one protocol, and is released either when the protocol closes the
connection or when the timeout limit is reached. If the AMR timeout is set to 120 seconds, then the
maximum time which the SCA waits for more communication is 120 seconds. If the timeout is
reached, the SCA closes the connection and returns to wait for new connection attempts.
A special setting in the timeout, 0 seconds, can be used to lengthen the timeout period to
approximately 6 hours for UDP and TCP, and 255 seconds in case of an http connection.