SISTORE MX RemoteView

19.15 Remote control of alarm outputs

19.16 Local revision of existing databases

19.17 Remote system reboot

114
Siemens Building Technologies
Fire Safety & Security Products
You can activate the alarm outputs, which were configured for this. To do so, you
must have the authorisation "remote control".
Fig. 65
Alarm outputs
You can activate the alarm outputs by clicking onto the LED-symbol. The alarm
outputs must have been defined as a special function (see Configuration Manual,
Section 10).
Alarm outputs which were configured with "pulse-negative/positive" mode cannot
be deactivated, because the length of the pulse was determined in the
configuration and cannot be changed manually.
NOTE
In contrast to the SISTORE MX server / SISTORE MX NVS server, the LEDs indicating the status of
the alarm outputs are in the bottom row of the display.
In SISTORE MX RemoteView databases may also be revised without a direct
connection to the recording SISTORE MX system (without LAN or ISDN
connections). Both Message and Record database must be available for this to
take place.
You open a database via the menu Administration -> Playback or by clicking the
button Play (s. header) in the toolbar. The dialog box "Select Directory" will then
appear, in which the directory containing the database should be entered and the
database clicked on. After confirmation using the Select button, the database is
loaded and the same dialog box as in the SISTORE MX "playback mode" will
appear. The revision can be carried out in the same way as in SISTORE MX, as all
functions are available.
With the menu sequence Action -> System reboot you can reboot SISTORE MX.
To do so you need "Administrator" authorisation.
You have to acknowledge 3 safety queries, then the reboot can be executed.
That SISTORE MX after a reboot starts again automatically, the following
conditions must be fulfilled:
Automatic login to Windows
SISTORE MX in the autostart file (the set-up enables this automatically,
condition on delivery)
Only after the restart a connection to SISTORE MX can take place. The restart can
take quite 1 minute or more.