Accessing the Avaya G250/G350 Media Gateway
6. By default, the re-authentication period is 3600 seconds. In other words, if re-authentication
is enabled on a port, the port attempts to re-authenticate the host every 3600 seconds. To
change the re-authentication period, use the set dot1x re-authperiod command,
followed by the length of the new re-authentication period in seconds (0 to 65535). For
example:
G250-001(super)# set port dot1x re-authperiod 10/4 400
G350-001(super)# set port dot1x re-authperiod 6/4 400

Manual re-authentication

You can perform a manual re-authentication at any time. To perform a manual re-authentication,
use the set prt dot1x re-authenticate command, followed by the module and port
number (or range of ports). For example:
G250-001(super)# set port dot1x re-authenticate 10/5-10
G350-001(super)# set port dot1x re-authenticate 6/5-10
When you perform a manual re-authentication, the port or ports attempt to re-authenticate the
host immediately.

Optional 802.1x commands

You can use the following commands to modify 802.1x parameters:
Use the clear dot1x config command to disable 802.1x on the G250/G350 and
return to default parameters.
Use the set port dot1x initialize command, followed by the module and port
number (or range of ports) to initialize a port or ports.
Use the set dot1x quiet-period command, followed by a time period in seconds (0
to 65535), to set the minimum idle time between authentication attempts for all ports on
which 802.1x is enabled.
Use the set port dot1x quiet-period command, followed by the module and port
number (or range of ports) and a time period in seconds (0 to 65535), to set the minimum
idle time between authentication attempts for a specific port or ports.
Use the set dot1x tx-period command, followed by a time period in seconds (1 to
65535), to set the time internal between attempts to access the Authenticated Station for
all ports on which 802.1x is enabled.
Use the set port dot1x tx-period command, followed by the module and port
number (or range of ports) and a time period in seconds (0 to 65535), to set the time
internal between attempts to access the Authenticated Station for a specific port or ports.
50 Administration for the Avaya G250 and Avaya G350 Media Gateways