8.7. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R≥15 mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R≥20 mm.
Conditions
Barcode Test Sample (1D and 2D): OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance
Angle
9. Interface Specifications
The OPI 2002 supports RS-232C, USB, and Wedge interfaces.
9.1. RS-232C Interface Spec
9600 bps to 115.2 kbps
Settings and Communication
9.1.1.
Reading the menu barcodes in section 11.1 can set the RS-232C interface
default. Kanji codes and image data can be transmitted via the RS-232C
interface.
Figure 6: Curvature
100 mm from the edge of the scanner
Skew β = +15°
19
Opticon
OPI 2002
Specifications Manual