8. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each
section.
Conditions
Ambient temperature
and humidity:
Ambient light:
Angles:
Background:
Power supply voltage:
Decoding test:
Barcode test samples:
8.1. Test Samples: 1D Symbologies
Code 39
Resolution
0.508 mm
0.339 mm
0.254 mm
0.127 mm
JAN/UPC/EAN
Resolution
0.260 mm
0.260 mm
GS1 Databar (RSS)
Resolution
0.254 mm
Room temperature (5 to 35º C)
Room humidity (45% to 85% RH)
500 to 1500 lx
Pitch: α = 0°, Skew: β = 15°, γ = 0°
Barcode = black
Space = white
Margin = white
Background of label = black
6.0 V
Carry out 10 scanning tests. Scanner is approved when scanning
is successful in 70% of the tests.
Code 39 (resolution 0.1 and 0.127 mm) and JAN codes used for
the tests are OPTOELECTRONICS test samples printed in a
normal printer. (NW ratio = 0:1.25)
Symbology
PCS
Code 39
0.9
Code 39
0.9
Code 39
0.9
Code 39
0.9
Symbology
PCS
13-digit JAN
0.9/0.45
8-digit JAN
0.9
Symbology
PCS
Standard
0.9
13
Specifications Manual
Size (mm)
Digits
29 x 25
2
19 x 15
2
14 x 10
2
11 x 10
4
Size (mm)
Digits
25 x 19
13
17.5 x 15.5
8
Size (mm)
Digits
24 x 8
16
Opticon
OPI 2002