Maintenance and Troubleshooting
4.3

Resetting the Inverter

Under some fault conditions (e.g., an internal fault), the inverter will need to be reset.
To reset the inverter:
Press and hold the Power ON/OFF pushbutton (see Figure 4-1) for approximately fi fteen (15)
seconds until the Charging/Inverting Status LED comes on and fl ashes rapidly; once the rapid
fl ashing has begun, release the Power ON/OFF pushbutton. The Status LED will go off after
the pushbutton is released.
After the inverter reset is completed, press the ON/OFF pushbutton to turn the inverter ON.
Info: The Power ON/OFF pushbutton is a small momentary type switch which operates
by lightly pressing and releasing.
Page 43

Figure 4-1, Performing an Inverter Reset

1. Press and hold the Power
ON/OFF pushbutton.
2. Watch the Charging/Inverting
Status LED, after approximately
15 seconds it should come on
and fl ash rapidly to indicate the
inverter has reset. The Status LED
will go off after the pushbutton is
released.