Introduction

1.0 Introduction
Congratulations on your purchase of the RD Series inverter/charger from Magnum Energy. The RD Series is a
modifi ed sine wave inverter designed especially for renewable energy use. Powerful, yet simple to operate, this
inverter/charger will provide you with the years of trouble-free performance you have come to expect from
Magnum Energy, all backed by our limited 2 year warranty.
Installation is easy. Simply connect the inverter's output to your distribution circuits or electrical
panel, connect your utility power cable (AC) to the inverter's easy-to-reach terminal block, connect
the batteries, and then switch it on for power.
Use the optional accessories listed below to control and monitor many other Magnum devices.
The RD Series inverter/charger includes the following:
1800, 2200, 2800, or 3900 watt models in a small footprint – less weight and area needed
for installation (shelf, bulkhead, or upside-down mounting)
Modifi ed Sine Wave output
Automatic Power Factor Corrected (PFC) multi-stage battery charging
RS485 standard communication protocol
Remote and Network ports (easy connection for optional accessories)
ON/OFF inverter-mounted switch with LED indicator
30 Amp per leg/input (can connect two inputs together to allow 60 Amp pass-thru)
Large AC access and terminal block [wire size: 10 to 6 AWG (5.3 to 13.3 mm
DC terminal covers with 360 degree connection
Field-serviceable for qualifi ed personnel – tested repair kits available
ETL listed to UL STD 1741, 1st edition for safety
Automatic battery temperature compensation (using battery temperature sensor) – for
optimum charging even during extreme temperature changes
Overcurrent, over-temperature, and high/low battery voltage protection
The following accessories are also available for use with the RD Series inverter/charger:
ME-RC50 (Basic Remote Control) - easy to read LCD display panel that enables standard
inverter and accessories set up, control, and troubleshooting.
ME-ARC50 (Advanced Remote Control) - easy to read LCD display panel that enables advance
inverter and accessories set up, control, and troubleshooting.
ME-AGS-N (Automatic Generator Start Module - Network version) - automatically starts/stops
your generator.
ME-BMK (Battery Monitor Kit - with Shunt) - provides precise DC voltage/current measurements
and provides information on your battery's State of Charge (SOC) condition.
ME-CB (Conduit Box) - provides 1/2" - 2" knockouts for connecting AC and DC conduit runs
to the inverter.
ME-SBC (Smart Battery Combiner) -
portion of the current that is charging a main battery.
MMP (Mini Magnum Panel) -
energy system into a single, easy to install pre-wired enclosure.
Page 1