Resetting The Inverter; Figure 4-1, Performing An Inverter Reset - Magnum Energy ME Series Owner's Manual

Me series modifi ed sine wave inverter/chargers
Hide thumbs Also See for ME Series:
Table of Contents

Advertisement

4.4

Resetting the Inverter

Under some fault conditions (e.g., an internal fault), the inverter will need to be reset.
To reset the inverter:
Press and hold the Power ON/OFF pushbutton (see Figure 4-1) for approximately fi fteen (15)
seconds until the Charging/Inverting Status LED comes on and fl ashes rapidly; once the rapid
fl ashing has begun, release the Power ON/OFF pushbutton. The Status LED will go off after
the pushbutton is released.
After the inverter reset is completed, press the ON/OFF pushbutton to turn the inverter ON.
Info: The Power ON/OFF pushbutton is a small momentary type switch which operates
by lightly pressing and releasing.
© 2010 Magnum Energy, Inc.

Figure 4-1, Performing an Inverter Reset

Maintenance and Troubleshooting
1. Press and hold the Power
ON/OFF pushbutton.
2. Watch the Charging/Inverting
Status LED, after approximately
15 seconds it should come on
and fl ash rapidly to indicate the
inverter has reset. The Status LED
will go off after the pushbutton is
released.
Page 48