2. Press F2.
The Settings window appears see Figure 12.
3. In the Settings window, navigate downwards using the Tab key. At the bottom of
the window, press Tab to go to the top of the window. Change settings by typing in
the selected area or by pressing the spacebar – whichever is relevant.
4. If DHCP is disabled, in the Settings window, type the IP Address, Subnet Mask, and
Gateway, as given by your Network Administrator.
Otherwise, if a DHCP server is active on the same network to which Smart
216/232 IP is connected, DHCP provides automatic IP assignment.
5. Once the IP address is satisfactory, proceed to log onto the Web interface to
complete the configuration.
3.2 Logging Onto the Web Configuration
Interface
You can complete the initial setup of the Smart 216/232 IP system via the Web
configuration interface.
Only one Administrator at a time can log onto the Web configuration interface. An idle
timeout of 30 minutes terminates the session.
Figure 11 – OSD Main Window
Figure 12 – Settings Window
Configuring the Network
Logging Onto the Web Configuration Interface
User Guide | 23