4-40 Configuring Your Workstation

Check Consistency

1.
Run LSI Software RAID Configuration Utility.
2.
Select [Check Consistency] from the TOP menu.
The [Virtual Drives] screen appears.
3.
Move the cursor onto the virtual drive to be checked, and press Space to select it.
4.
When virtual drive has been selected, press F10 to start consistency check.
5.
A confirmation screen for execution appears. Select [Yes].
The consistency check starts.
When the progress bar in the [CC Under Progress] screen indicates 100%, the consistency
check is completed.
6.
Press Esc to return to the TOP menu and exit LSI Software RAID Configuration Utility.
IMPORTANT:
Be sure to execute Check Consistency after creating configuration.
Do not perform Check Consistency for the hard disk drive in
RAID0.
Run LSI Software RAID Configuration Utility
Perform Check Consistency
Exit LSI Software RAID Configuration Utility