ArtNet BASE CHANNEL:
on 64 consecutive channels, or 10 consecutive channels when advanced mode is not
enabled. The projector processes requests that come on either 10 or 64 consecutive
channels beginning with the 'base channel' defined here. The requests implement the
following functions:
DMX Channel
Base
Base + 1
Base + 2
Base + 3
Base + 4
Base + 5
Base + 6
Base + 7
Base + 8
Base + 9
* Functions are only active when the Slider Lock is set to Unlocked
NOTE: It is important to ensure the channels DO NOT overlap another device.
Example:
ARTNET DEVICE NAME:
support querying for devices. Press Enter and use the arrow keys to enter a name.
NOTE: Refer to section 3.4 Navigating the Menus, Edit numerical Values, for text
entry description.
ARTNET DEVICE DESCRIPTION:
query" has been done.

Broadcast Key

Enter a checkmark if you want keypad commands sent to one projector to be relayed
to all projectors in a serial network. Note that the
the effect of a broadcast setting and allow you to control a specific projector when
necessary. Disable the setting for all but one (any) projector in a network.
Mirage S+/HD/WU, Matrix S+/HD/WU, Christie HD/DS+/DW, DLV User Manual
When advanced mode is enabled, the projector listens to data
Function
Shutter
Slider Lock
Input *
Channel *
Lens – Vertical * †
Lens – Horizontal * †
Lens – Focus * †
Lens – Zoom * †
Power *
None
Good
Proj1_Base = 0
Proj1_Base = 5
Proj2_Base = 10
Proj2_Base = 9
Proj3_Base = 20
Proj3_Base = 11
This option is used to name each device; some ArtNet servers
More information that is returned when a "device
Value
0 – 64
Open
65 – 192
No Action
193 – 255
Closed
0 – 254
Locked
255
Unlocked *
1 – 8
Input #
1-99
Channel #
0
Lens Down
1 – 254
Stop
255
Lens Up
0
Lens Right
1 – 254
Stop
255
Lens Left
0
Negative Focus
1 – 254
Stop
255
Positive Focus
0
Zoom Out
1 – 254
Stop
255
Zoom In
0
Power Off
1 – 254
No Action
255
Power On