Christie Mirage S+ User Manual page 63

Mirage s+/hd/wu, matrix s+/hd/wu, christie hd/ds+/dw, dlv series
Hide thumbs Also See for Mirage S+:
Table of Contents

Advertisement

Mirage S+/HD/WU, Matrix S+/HD/WU, Christie HD/DS+/DW, DLV User Manual
020-100001-07 Rev. 1 (11-2009)
The optical aperture inside the projector controls the diameter
OPTICAL APERTURE -
of the light beam passing through the system. With a fully open aperture (slide bar
default of "0"), the maximum amount of light passes through for maximum brightness
in your images. Increase the slide bar setting to reduce the aperture diameter and
maximize contrast ratio instead. Performance of aperture depends on the lens in use.
NOTE: Optical Aperture also appears in the lamp menu.
Aperture Manual Adjustment
1.2:1 and 1.1:1 lens. It may be used together with the internal electronic aperture to
increase the contrast ratio; noting a slight decrease in brightness when it is used. It is
recommended for highest brightness operation, under normal conditions, the manual
aperture is to be left open. See Aperture Manual Adjustment below for aperture
open/close and lock and unlock dial positions. NOTE: The lock/unlock dial position
allows you to open the aperture at a desired position and lock it in place.
- No function.
RESERVED
Mirage S+ Series — Simulation 3D —
SETTINGS
Use the options in the Simulation 3D
menu to make the timing adjustments
necessary for realistic simulation and
3D images.
NOTE: For complete 3D application
notes, refer to the separate Using 3D
in Mirage manual provided with the
Mirage projector.
FRAME DELAY MONITOR —
results, the value should remain fairly
constant, indicating that timing of input and output frames is locked; the Frame Delay
Monitor value should stay within 5-10 lines or so of the Frame Delay setting. If a
frame is lost or "dropped", this value will cycle to maximum and jump to minimum
and then repeat, indicating that the frame input is no longer equal to the output. If the
signal is not locked, the values will change erratically; you can adjust the Frame delay
to attempt a correction.
NOTE: See separate Using 3D in Mirage manual provided for more information.
- A variable position manual aperture is present on the
CLOSE
UNLOCK
Aperture Manual Adjustment
SUBMENU OF ADVANCED IMAGE
Frame Delay Monitor
1.
2.
3.
3D Stero Sync Locking
4.
3D Stero Sync Select
5.
3D Stereo Sync Delay
6.
Frame Lock Enable
7.
For best
Section 3: Operation
OPEN
LOCK
Simulation 3D
1047
1000
Frame Delay
Dark Interval
128
Output
Input A
1000
Locked
Reserved
Mirage S+ Models
3-33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents