Section 4: Maintenance

Filter Replacement

Procedure
4-10
Lamp Hours
Lamp S/N
1.
Lamp Message
2.
Lamp Limit
3.
Lamp Mode
4.
Power
5.
Intensity
6.
Optical Aperture
7.
Lamp History
8.
Change Lamp
Figure 4.6. Lamp Menu
IMPORTANT: If you neglect to enter a serial number, the lamp timer will not
reset to "0" and will therefore be inaccurate. The lamp life limit may then expire
prematurely.
Use Christie approved
The two filters located at the front
and left side of the projector should
be replaced whenever the lamp is
replaced. If you are working in an
extremely dusty environment you
may want to replace the filters sooner.
Use the filters provided in the Christie
approved Lamp and Filter Kit for your
specific projector model.
1. TURN OFF THE PROJECTOR, COOL and UNPLUG
Before removing or installing a filter, turn off the projector and allow it to cool for
five minutes before unplugging.
2. REMOVE FILTER ACCESS
PANELS
Loosen the captive screw(s) on the filter
access panels using a #2 Phillips
screwdriver. (Front access panel located
to the left of the lens – one screw. Left
side access panel – three screws. See
Figure 4.6.
Lamp
0
?
1000
Power
500
0
3
WARNING
filters ONLY.
Mirage S+/HD/WU, Matrix S+/HD/WU, Christie HD/DS+/DW, DLV User Manual
New serial# entry
automatically updates
Lamp History...
Lamp S/N
...and resets Lamp
Hours to "0"
Figure 4.7. Filter Location
Figure 4.8. Remove Filter Access Panels
020-100001-07 Rev. 1 (11-2009)
Lamp History
S/N
Hours
5679
1001
1234
0