8-18
PLC-5C to Logix5550 Controller: Scheduled Communications
Create the Producer
Application
1756-6.5.3 - December 1999
Perform the following steps to create the PLC-5C producer application:
1. Start the RSLogix5 software.
2. From the File menu, select New. The Select Processor Type window will
appear.
3. Enter the following information and click on OK.
In this field
Processor Name
Platform
Processor
Series
Revision
Driver
Processor Node
(1)
F series is recommended but not required.
You will receive the following prompt:
4. Click on the Browse button and select the ControlNet Project file created
in RSNetWorx for ControlNet (e.g., "Sched_PLC_to_Logix5550").
5. Set the ControlNet Node to 11.
6. Click on OK.
Select
PRODUCER
ControlNet
(Enter your processor type)
(Enter your processor's series)
(Enter revision letter)
AB_KTC-1
11
(1)