Environment

Table 8-5
provides the environmental requirements necessary to operate the FastStor 2.
Table 8-5
Environmental Specifications
Characteristic
Temperature
Operating
Non-operating
Recommended operating temperature
Temperature shock immunity - maximum rate of
change
Humidity
Operating
Non-operating
Altitude
Operating
Non-operating
Vibration (3-500 Hz)
Maximum acceleration to operating

Tape Drive

Table 8-6
provides the requirements necessary to operate a FastStor 2 configured with an LTO-1
tape drive.
Table 8-6
LTO-1 Drive Specifications
Description
Read/write transfer rate: maximum sustained
Burst transfer rate
Average access time
Temperature shock immunity– maximum rate
of change
Environment
Specification
10º to 35º C (50º to 95º F)
–40º to 60º C (–40º to 140º F)
20º to 30º C (68º to 86º F)
10º C per hour (50º F)
20% to 80% RH non-condensing
10% to 90% RH non-condensing
0 to 3,048 m (0 to 10,000 ft)
0 to 13,716 m (0 to 45,000 ft)
0.6 g
LTO-1
Non-compressed mode:15 MB/second
Compressed (2:1 typical): 30 MB/second
80 MB/second
71 seconds
20º to 30º C (68º to 86º F) – 10º C per hour
(50º F)
61