Operating Environment
Operating Temperature: 10 C to 40 C (41 F to 113 F)
Storage Temperature: –40 C to 70 C (–40 F to 158 F)
Humidity: 10%-85% Operating, Non-Condensing, 5%-95% Non-operating, Non-Condensing
To provide a safety margin and permit adequate cooling, the SNC 6101 is fitted
Note
with a 12 VDC tach-output blower. Should temperatures exceed specifications,
an environmental alarm violation is sent and logged, permitting environmental
causes of failure to be determined. This information is available from the ADIC
Management Console.
Supported Platforms
The SNC is platform-independent. You can connect a host to the SNC 6101 after you have installed the
appropriate host bus adapter and drivers. You can also connect host systems with different operating
systems to the SNC 6101 through FC. For a current list of supported platforms, configurations, and host bus
adapters, see www.adic.com.
Supported Devices
The SNC 6101 supports connections to the Scalar 100 tape library and supports all tape drives available
for that unit. For a current list of supported devices, refer to www.adic.com.
Compliance
The FC interface controller is in compliance with the following standards and specifications:
•
Fibre Channel Arbitrated Loop (FC-AL-2) working draft, rev 6.4, August 28, 1998
•
Fibre Channel Fabric Loop Attachment (FC-FLA) working draft, rev 2.7, August 12, 1997
•
Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) working draft, rev 2.1, Sept. 22,
1997
•
Fibre Channel Tape (FC-TAPE) profile, T11/98-124vD, rev 1.13, February 3, 1999
•
Fibre Channel protocol SCSI (FCP-SCSI)
•
Fibre Channel internet protocol (IP)
•
Fibre Channel virtual interface (FC-VI)
•
Fibre Channel Class 3 support
The SCSI interfaces are compliant with the following SCSI specifications:
•
ANSI T10/1071D Rev. 6, SCSI-3 Fast-20
•
ANSI T10/375D Rev. 10t, SCSI-2
•
ANSI T10/1142D Rev 20b, SCSI-3 Parallel Interface-2
SNC 6101 User's Guide