Sequence Functions - Dynacord DMM 4650 Owner's Manual

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

Each of the 4 ports also supplies a power source in order to facilitate the connection of floating contacts. The ground
and earthing conditions are shown in the above diagram. The strict separation of control and audio signals guarantees
the trouble-free installation.
Sequence function
The following example shows in sequence the necessary steps from closing the contact of an external switch to
listening to the audio signal:
A switch is connected to one of the DMM 4650's control inputs (Al - D4). The desired input is selected in the trigger
menu. Logic level (high, low), delay, and function (dyn, stc, latch) can be set. The desired sequence (Sxx) gets
chosen here as well.
For this sequence, the actions of the DMM 4650 are programmed step by step. Standard sequences are provided as
factory presets. They can be modified as need arises and stored as user presets.
Example of a sequence: set output (lamp indicator), audio control SUM off, audio control DMM -3 dB, wait for input
release, after release start alarm, delay 10 sec. (alarm duration), end.
This sequence is entered line-by-line with special commands (list page 25) and - including name and
priority - stored as a preset. If an appliance uses unaltered functions on a regular basis, it is also possible to save
these sequences via the RS 232 interface.