List Of Available Step Functions In A Sequence - Dynacord DMM 4650 Owner's Manual

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

List of available step functions in sequences
Command
parameter
Nop
End
Out
X.Y set
X.Y clr
X.Y inv
Start
Axx
Gxx
Mxx
Ann.
Break
Finish
DMM=
-xx dB
Sum=
-xx dB
Bypass
set
cir
inv
Audio
pri
sum
Record
Mxx
Dly=
ttt,t S
Count=
xxxx
Jump
xx
If
Delay
Count
Audio
In X,Y Z
Stop
wt
Delay
Audio
In X,Y Z
Stop
*setting which is utilized, if a command is not used
-no operation
-ending the running sequence
-Output Y (1 ..4) of the 1/0 module X (A..D) is set to 1 (contact closed)
-Output Y (1 ..4) of the 1/0 module X (A..D) is set to 0 (contact open)
-Output Y (1 ..4) of the 1/0 module X (A..D) is inverted
-ends a currently running audio signal immediately and starts the alarm preset xx
-ends a currently running audio signal immediately and starts the gong preset xx
-ends a currently running audio signal immediately and starts the message xx
-ends a currently running audio signal immediately and starts the announcement
-ends a currently running audio signal immediately
-requests the end of the running audio signal. Gong, alarm fade out, messages and
announcements are finished, recording is stopped.
-controls of the DMM 4650 audio signal is set to -xx dB (*0 dB default)
-control of the input - output XLR connection is set to -xx dB
-analog bypass relay, direct connection XLR input - output closed
-analog bypass relay, no relay connection XLR input - output
-inverted analog bypass relay
-switches the started DMM audio signals to pre-listen outputs (Pre-Listen only)
-switches the started DMM audio signals to pre-listen and sum outputs (*default)
-ends a currently running audio signal immediately and starts the recording of the
message xx. At first this message is being erased and then recording starts at the last
adjusted recording level. Audio quality and name of this message stay unchanged.
The message priority is identical with the sequence priority. The execution time lasts
until End Delete Message (start of recording).
-sets a timer to ttt,t seconds and starts measuring this time (sand glass).
-sets a counter (event counter) to a starting value, xxxx. With every "if count"-command
the counter is decremented by 1 until 0 is reached.
-resumes the sequence at step number xx.
-only executes the next step number if the delay time has elapsed (see command Dly).
Otherwise the next step number is being skipped.
-the counter is decremented by 1. The next step number is executed only if the counter
has reached 0 (see command Count). If the counter value is greater than 0, the next
step number is being skipped.
-executes the next step number only if the audio signal started at last is finished
(see command start), otherwise the next step number is being skipped.
-executes the next step number only if the desired level Z (H or L) is applied at input
Y (1 ..4) of the i/0 module X (A..D). If this condition is not fulfilled, the next step number is being
skipped.
-executes the next step number only if the stop trigger condition of this seque fulfilled. Otherwise
the next step number is being skipped.
-waits until the delay time is elapsed
-waits until the last started audio signal is finished
-waits until the desired level Z (H or L) is applied at input Y (1 ..4) of the 110
module X (A..D).
-waits until the stop trigger condition of this sequence is fulfilled.
Function